Paper Title :A Study On Seismic Performance Of Adjacent Structures Connected With Fluid Viscous Dampers
Author :Avinash A.R., Padigela Abhinai, Karthik.B, Kiran Kamath
Article Citation :Avinash A.R. ,Padigela Abhinai ,Karthik.B ,Kiran Kamath ,
(2016 ) " A Study On Seismic Performance Of Adjacent Structures Connected With Fluid Viscous Dampers " ,
International Journal of Advances in Mechanical and Civil Engineering (IJAMCE) ,
pp. 21-25,
Volume-3,Issue-4
Abstract : Seismic performance of two adjacent buildings connected with Fluid Viscous Dampers (FVDs) has been studied
in the present work. 3D models of two adjacent buildings are developed using the software ETABS® evaluation version.
Height of one building (h) is kept constant at 15 m, whereas the height of adjacent building (H) is varied by increasing the
number of storey’s. The H/h ratio is called as height ratio, this ratio is varied from 1 to 3. The adjacent structures with and
without FVD connections are subjected to accelerograms of different earthquakes. FVDs are connected at storey levels of
both the buildings. Responses of the adjacent structures are compared with and without FVD connections. Responses
considered in the study are roof displacements, roof accelerations and base shears. Results indicate that adding FVDs have
modified seismic responses of connected structures.
Keywords— Time history, Fluid Viscous Dampers, Height ratio(H/h).
Type : Research paper
Published : Volume-3,Issue-4
DOIONLINE NO - IJAMCE-IRAJ-DOIONLINE-5227
View Here
Copyright: © Institute of Research and Journals
|
|
| |
|
PDF |
| |
Viewed - 61 |
| |
Published on 2016-08-22 |
|